Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
System Components

(1)Air Conditioning System
· Rack-mounted Split Unit: 3.5kW, 7.5kW, 12.5kW
· Rack-mounted Integrated Unit: 3.5kW, 5kW
· Row-Level Units: 12.8kW, 21.2kW, 25.1kW, 31.1kW, 40.9kW, 51.2kW, 65.7kW

 

(2)Cabinet System
· Cabinet Dimensions: Width: 600/800mm; Depth: 1200mm; Height: 2000mm
· Cabinet Access Control: Four-in-One Smart Access Control (Fingerprint + Password + ID Card + Mechanical Lock)
· Other Accessories: Ambient Lighting, Lighting, 1U Blank Panel, Shelf, L-shaped Rails, Cable Management Rack, Cable Ties, Top Cable Tray, IP55 Adaptation Components, etc.

 

(3)UPS Power Supply System
· UPS: Rack-mounted: 3~60kVA
· Modular UPS: 15~200kVA
· Batteries: Lead-acid Batteries, Lithium Batteries
· Power Distribution Module: Rack-mounted design, supports custom configurations, includes surge protection, monitoring

 

(4)Monitoring and Security
· Monitoring Sensors: Temperature & Humidity, Smoke Detection, Water Leakage, Door Contact, Audio-Visual Alarms, SMS Alerts, Mobile App, Centralized Monitoring System
· Video Surveillance: Cameras, NVRs, and Hard Drives
· Fire Protection: Rack-mounted Gas Fire Extinguishing System

Typical Configuration

Technical Specifications Table

Model

6T

10T

20T

20S

30S

Customization

Cabinets

1

3

5

5

7

≤20

Power Density

-kw/unit

3

3

3

4

4

≤20kw/unit

Redundancy Type

N

N

N

N

N+1

N/N+1/2N

Depth-mm

1200

1200

1200

1200

1200

Customizable to 1400

Width-mm

600

600

600

600

600

Optional 800

Height-mm

2000

2000

2000

2000

2000

Customizable to 2200 -47U

Power System

UPS -kVA

6

10

20

20

30+30

3~200

Total Input Power Specification

63A/1P

220V~50Hz

63A/3P

380V~50Hz

63A/3P

380V~50Hz

100A/3P

380V~50Hz

100A/3P

380V~50Hz

Customizable

Cooling System

Cooling Type

Air Cooling

Air Cooling

Air Cooling

Air Cooling

Air Cooling

Air Cooling/Liquid Cooling

Cooling Capacity-kW

3.5

7.5

7.5+7.5

21.2

25+25

3.5~65

Cooling Type

Rack-mounted

Rack-mounted

Rack-mounted

Row-level

Row-level

Rack-mounted

/Row-level

Management System

Environmental Monitoring System

UPS, Power Distribution, Precision Air Conditioning, 10-inch Touchscreen, Temperature & Humidity, Smoke Detection, Water Leakage, Door Contact

Optional: Audio-Visual/ SMS Alerts, App, Centralized Monitoring, etc.

Security System

Four-in-One Access Control System

Optional: Video Surveillance, Fire Protection