Capacity from 237 to 1709W (water, Tw1=40°C, Tw2=35°C, T1=25°C). Fans diameter: Ø350, 450, 500, 630, 800, 910, 1250, 1800mm, AC or EC motor.
Click to ContinueCompared with traditional dry coolers, the adiabatic type has higher cooling capacity and energy efficiency, which is the first choice for industrial cooling applications. With an evaporative cooling system, water is sprayed onto the coils, which improves heat transfer, reduces temperatures, and saves energy, money, and carbon footprint.
Click to ContinueUse water as the cooling medium and driven by a screw compressor. It is suitable for large commercial buildings and industrial applications, providing efficient cooling capacity.
Click to ContinueA type of condenser that does not require water for cooling. It utilizes forced air circulation to cool down steam and convert it into liquid form. This design is particularly suitable for environments where water cooling is not feasible or in special application scenarios.
Click to ContinueHybrid Dry Cooler combines the advantages of both wet and dry cooling. In wet cooling mode, the evaporation of water takes away a significant amount of heat, providing a more efficient cooling effect. In dry cooling mode, no additional water resources are required, making it suitable for dry environments.
Click to ContinueHybrid Dry Cooler can switch between different operating modes according to actual needs. It can be used in wet cooling mode in high temperature and high humidity environments, and in dry cooling mode in dry environments. This makes it suitable for various climate conditions and different application scenarios.
Click to ContinueCapacity from 5 to 1920kW (water, Tw1=40°C, Tw2=35°C, T1=25°C). Fans diameter: Ø350, 450, 500, 630, 800, 910, 1250, 1800mm, AC or EC motor.
Click to ContinueCool outside air or water can be used as a free resource to help chill water which can be used for industrial processes or air conditioning. By using air-cooled dry coolers which remove unwanted heat without the need for integration with the chiller control. So in this application we can also called dry cooler as free cooler...
Click to ContinueCMA Room-Based Air-cooled Air Conditioner provides precise temperature and humidity control for large and medium-sized data centers. It uses efficient compressors and is equipped with EC centrifugal fans to meet the continuous operation requirements of 24x7. It is an ideal choice for green and energy-efficient data centers and various electronic equipment rooms.
Click to ContinueThe chilled water fan wall unit of our CMC series is a member large-scale computer room air conditioner, providing precise temperature and humidity control for the computer room. Usually, it combines with chillers, pumps, chilled water pipelines, and other components as a cooling system. High reliability, stability, and energy-saving, helping to build the next generation of green data centers.
Click to ContinueRemote radiator systems are often used when there is insufficient ventilation air in a room or enclosure to properly cool the generator set. Dry coolers can also be as a remote radiator for generator heat transfer and cooling.
Click to ContinueRemote radiator systems are often used when there is insufficient ventilation air in a room or enclosure to properly cool the generator set.Dry coolers can also be as a remote radiator for generator heat transfer and cooling.
Click to ContinueDry coolers are the most cost-effective way to dissipate heat from immersion cooling systems. Immersion cooling, also known as liquid immersion cooling, submerges computer components or entire servers in a thermally conductive but nonconductive liquid (dielectric coolant), which offers higher heat transfer properties than air and many other advantages.
Click to ContinueInfusing essential benefits in HVAC areas, including increased equipment efficiency, reduced size and weight of equipment, and lower system end-cost. Includes a wide range of sizes for various refrigerants, Venttech provides clients various combinations of multi-port tubes, fin types and fin spacings, connections, mountings, and protective coatings.
Click to Continue