Introduction:
The CRC Row-Based Air Conditioner (Chilled water), while maintaining the characteristics of close proximity to heat sources and precise cooling, is more suitable for scenarios with limited on-site installation (no need to install a separate outdoor unit), supporting the continuous development of green data centers.
Application:
● Small-to-medium sized Data Centers
● Modular Data Centers
● Cabinet Row Cooling (or heat) channel retrofitting
● Medium-to-high heat-density Communication Equipment
● Computer Rooms
Features:
● The key components are selected from well-known brands.
● A fully EC variable frequency design, automatically adjusting cooling and airflow output.
● The humidification component has zero power consumption and is energy-efficient.
● The "full cabinet-style straight or U-shaped" evaporator has a large area and low air resistance.
● The high-return air temperature design significantly improves energy efficiency.
● Three operation modes automatically switch and adjust in real time.
● The pump cabinet system is designed in series, highly integrated, and more energy-efficient.
● The pump cabinet is integrated on the outside, eliminating the need for separate space.
● Integrate efficient energy-saving algorithms and supports group control, rotation, and cascading.
Technical Data:
CRC Row-Based Air Conditioner (Chilled water) |
||
Indoor unit model |
CRC0030 |
CRC0060 |
Air supply |
Front air supply |
|
Performance parameter |
||
Cooling capacity(kW) |
30 |
60 |
Sensible capacity(kW) |
30 |
60 |
Rated voltage/HZ |
220V1Ph~50Hz |
380V3Ph~50Hz |
Max. operation current FLA (A) |
17.5 |
13.0 |
Fan type |
EC centrifugal fan |
|
Fan QTY |
6 |
2 |
Circulating air volume(m³/h) |
5000 |
11500 |
Heating capacity (kW) |
3 |
6 |
Humidification (kg /h) |
1.5 |
3 |
Connecting pipe size(30m) |
||
Water inlet pipe size(mm) |
DN25 |
DN32 |
Water outlet pipe size(mm) |
DN25 |
DN32 |
Humidification inlet pipe(Internal thread) |
G3/4" |
|
Water pump drain pipe(mm) |
ID12 |
|
Natural drain pipe(mm) |
ID16*OD24 |
|
Unit dimension and weight |
||
Dimension-W(mm) |
300 |
600 |
Dimension-D(mm) |
1200 |
|
Dimension-H(mm) |
2000 |
|
Weight(kg) |
165 |
205 |
Electronic element specification |
||
Air switch recommended (A) |
40 |
25 |
Cable size (mm²) |
6 |
4 |
Note: |
Downloads