HDA Precision Air Conditioner for Computer Room

Products

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Features

Introduction:

 

HDA Precision aircon is designed to provide a comprehensive cooling solution for medium to low-heat-density data center rooms. The unit features "high-efficiency fans" combined with adjustable air guide grids, employing stepless speed control design. The overall energy efficiency ratio can reach up to 3.6, far exceeding the national first-level energy efficiency standards, positioning it at an industry-leading level.

 

Application:

 

  Small to medium-sized computer rooms

  Equipment rooms

  High-end communication base stations

  Various Equipment spaces, Battery rooms, Power rooms, Substations, Distribution rooms, and control rooms.

 

 

Features:

 

Dual-fan backup with one fan able to provide 50% airflow in case of the other fan's failure.

Innovative "Dual DC Axial Flow Design" for fans, achieving 20% energy savings.

Humidification using wet membranes, with no reheating, resulting in over 90% energy savings in humidification consumption.

Comes with a standard electrical metering function module, providing clear daily power consumption data.

Achieves ultra-first-level energy efficiency with a rating of up to 3.6, saving 10% to 20% on energy costs.

 

Technical Data:

 

HDA Precision Aircon for Computer Room

Indoor unit model

HDA1008

HDA1013

HDA1020

Main power supply

380V3Ph~50Hz

Air supply

Up and front air supply

Performance  parameter

Cooling capacity(kW)

8.0

13.0

20.2

Sensible capacity(kW)

7.36

11.7

18.18

Max. operation current FLA(A)

15.0

18.7

25.0

Compressor   QTY

1

1

1

Fan type

DC axial flow fan

Fan QTY

2

Circulating air volume(m3 /h)

2800

3500

5000

Heating capacity(kW)

2

Humidification(kg/h)

2

Connecting pipe size

Liquid  pipe(mm)

6

9.52

12.7

Gas  pipe(mm)

15.88

19.05

19.05

Humidification inlet pipe(Internal thread)

G3/4

Drain pipe

Inner diameter 19mm, outer diameter 25mm, metal hose clamp connection

ndoor unit dimension and weight

Dimension-W(mm)

580

Dimension-D(mm)

365

365

460

Dimension-H(mm)

1950

weight(kg)

100

113

148

Outdoor unit performance parameter

Outdoor unit model

CST008SP1A

CST013SP1A

CSTO20SP1A

Dimension-W(mm)

728

728

1020

Dimension-D(mm)

405

Dimension-H(mm)

762

1370

1370

Weight(kg)

34

53

74

Electronic element specification

Air switch(recommended)

32

Indoor power cable diameter

4*4.0+1*4.0                      4*4.0+1*4.0

4*6.0+1*6.0

Outdoor power cable diameter

2*1.0+1*1.0

Note:
1.Standard working conditions: indoor ambient temperature 24℃, RH 50%, outdoor ambient temperature 35℃;
2.Only cooling+electric heating or constant temperature and humidity type can beselected. The maximum working current and the recommended air switch are configured according to the constant temperature and humidity unit.

 