Project Overview
Reliable cooling is essential for maintaining stable operating conditions in modern data centers, where continuous IT operation requires consistent thermal management. For a data center cooling water application in Palestine, VENTTK provides a 380 kW Water Cooled Chiller designed to support stable chilled-water cooling under the specified project conditions.
The unit combines a water-cooled refrigeration system with Bitzer compressor technology and Siemens control components, providing a compact and professionally configured cooling solution for data center infrastructure.
Project Information
· Country: Palestine
· Application: Data Center Cooling Water
· Product: Water Cooled Chiller
· Model: SW-340DY
· Cooling Capacity: 380 kW
· Refrigerant: R404A
· Power Supply: 3P / 400 V / 50 Hz
· Inlet / Outlet Water Temperature: -5 / -10°C
· Control: Siemens
· Compressor: Bitzer
.webp)
Project Features
The 380 kW cooling capacity provides a substantial cooling output for the project's data center cooling-water system. The specified -5°C / -10°C inlet and outlet temperature conditions support the project's low-temperature cooling requirements and allow the chiller to operate according to the defined system design.
The chiller adopts R404A refrigerant and is equipped with a Bitzer compressor, combining established refrigeration components with a configuration suited to continuous cooling applications. The Siemens control system further provides a reliable control platform for unit operation and system management.
With a 3-phase, 400 V, 50 Hz power supply, the unit is configured according to the project's electrical requirements. The water-cooled design is also suitable for centralized cooling systems where heat rejection is handled through the associated water-side infrastructure.
Project Significance
This project demonstrates VENTTK's capability to provide water cooled chiller solutions for data center cooling applications based on specific thermal, temperature and electrical requirements. Rather than applying a standardized configuration to every project, the chiller is specified according to the required cooling capacity, operating temperatures and site conditions.
For data center operators, EPC contractors and cooling-system integrators, appropriately selected chiller equipment is an important part of maintaining stable thermal conditions and supporting continuous IT infrastructure operation. Through project-based configuration and engineering support, VENTTK continues to provide practical cooling solutions for international data center .